Integral Quench Horizontal Vacuum Furnace Specifications |
| |
| Model |
Work Space Dimensions (1) |
Input kW |
Max. Load (2) |
| Width |
Depth |
Height |
@2100 |
@2400 |
| 29-GR-152412-21VIQ |
15 |
24 |
12 |
60 |
225 |
NA |
| 29-GR-243624-24VIQ |
24 |
36 |
24 |
150 |
1,075 |
660 |
| 29-GR-304830-21VIQ |
30 |
48 |
30 |
200 |
2,250 |
NA |
| 29-GR-364836-24VIQ |
36 |
48 |
36 |
200 |
3,200 |
1,980 |
| Note (1) - Inches, actual inside chamber is larger. |
| Note (2) - Pounds. Loads are nominal. Contact factory for other ratings. |
| Model |
Approx. Weight (lbs.) |
Mech Pump |
Blower (1) |
Max Water GPM (3) |
Cool Fan HP |
Carb Fan HP |
| HP |
CFM |
HP |
CFM |
| 29-GR-152412-21VIQ |
19,000 |
7.5 |
150 |
2 |
300 |
35 |
15 |
NA |
| 29-GR-243624-24VIQ |
28,000 |
7.5 |
150 |
3 |
600 |
100 |
20 |
NA |
| 29-GR-304830-21VIQ |
50,000 |
10 |
300 |
10 |
1,600 |
195 |
2@7.5 |
7.5 |
| 29-GR-364836-24VIQ |
70,000 |
10 |
300 |
10 |
1,600 |
225 |
2@7.5 |
NA |
| Note (1) - For fast cooling, normal is 60-80% of that shown. |
| Model |
Backfill Gas CF |
Surge Tank |
Oil Quench |
| CF |
Weight |
Approx. Gallons |
Agitator Hp |
Preheat kW |
Hot Oil kW |
Cool Pump HP |
| 29-GR-152412-21VIQ |
75 |
19 |
375 |
600 |
5 |
18 |
NA |
1.5 |
| 29-GR-243624-24VIQ |
200 |
34 |
640 |
1,500 |
7.5 |
27 |
NA |
3 |
| 29-GR-304830-21VIQ |
300 |
57 |
725 |
3,000 |
4@5 |
36 |
NA |
5 |
| 29-GR-364836-24VIQ |
400 |
57 |
725 |
2,700 |
2@7.5 |
36 |
NA |
5 |
| All models: Maximum cooling backfill pressure 2.5 psig. |
| All models: Ultimate vacuum 1 x 10-2 Torr. |
|
|