Specifications
Lindberg Industrial Products <<Go
Back
|
Info & pricing
269-849-2700
lindberg@tps.spx.com
|
|
HYEN Endothermic Generator
Electric
| Model |
Approximate Dimensions (in.) |
Removal Height |
| Width |
Length |
Height |
| 16-RO-500-A-HYEN |
50 |
101 |
98 |
144 |
| 16-RO-1000-A4 HYEN |
50 |
101 |
98 |
156 |
| 16-RO-1500-A4 HYEN |
50 |
101 |
98 |
168 |
| 16-RO-3000-A4 HYEN |
103 |
81 |
142 |
177 |
| 16-RO-4500-A4 HYEN |
103 |
93 |
142 |
177 |
| 16-RO-6000-A4 HYEN |
103 |
119 |
142 |
177 |
| Model |
Output CFH |
Heating kW (1) |
Gas (2) |
Approx. Wt. (lbs) |
Mixer HP |
IPS Gas In |
IPS Atmos. |
Number of Retorts |
|
| 16-RO-500-A-HYEN |
500 |
16 |
110 |
3,800 |
0.33 |
1 |
1-1/4 |
1 |
| 16-RO-1000-A4 HYEN |
1,000 |
20 |
220 |
4,800 |
1 |
1 |
1-1/4 |
1 |
| 16-RO-1500-A4 HYEN |
1,500 |
25 |
330 |
5,000 |
1 |
1 |
1-1/4 |
1 |
| 16-RO-3000-A4 HYEN |
3,000 |
50 |
660 |
10,500 |
1.5 |
1-1/2 |
2 |
2 |
| 16-R0-4500-A4 HYEN |
4,500 |
75 |
990 |
14,000 |
2 |
1-1/2 |
2-1/4 |
3 |
| 16-RO-6000-A4 HYEN |
6,000 |
100 |
1,320 |
18,000 |
2 |
1-1/2 |
3 |
4 |
| Note (1) - energy to heat system |
| Note (2) - fuel used to create the HYEN gas. Based on nominal 1000BTU/CF natural gas. |
| For propane, fuel CFH requirements relate to equivalent BTU values. |
Gas-Fired
| Model |
Approximate Dimensions (in.) |
Removal Height |
| Width |
Length |
Height |
| 16-500-A-HYEN |
50 |
101 |
98 |
145 |
| 16-1000-A4 HYEN |
56 |
101 |
98 |
156 |
| 16-1500-A4 HYEN |
56 |
101 |
98 |
168 |
| 16-3000-A4 HYEN |
111 |
81 |
142 |
177 |
| 16-4500-A4 HYEN |
111 |
93 |
126 |
174 |
| 16-6000-A4 HYEN |
111 |
119 |
142 |
177 |
| Model |
Output CFH |
Fuel Input |
Approx. Wt. (lbs) |
Mixer HP |
Combustion Blower |
IPS Gas In |
IPS Atmos. |
Number of Burners |
Number of Retorts |
| Total CFH |
Heating CFH 2 |
Reaction CFH (3) |
CFH |
HP |
| 16-500-A-HYEN |
500 |
250 |
140 |
110 |
3,800 |
0.33 |
3,650 |
1/2 |
1-1/4 |
1-1/4 |
1 |
1 |
| 16-1000-A4 HYEN |
1,000 |
390 |
170 |
220 |
4,800 |
0.75 |
3,650 |
1/2 |
1-1/4 |
1-1/4 |
2 |
1 |
| 16-1500-A4 HYEN |
1,500 |
526 |
196 |
330 |
5,000 |
1 |
10,000 |
3/4 |
1-1/4 |
1-1/4 |
2 |
1 |
| 16-3000-A4 HYEN |
3,000 |
1,145 |
485 |
660 |
10,500 |
1.5 |
10,000 |
3/4 |
1-1/2 |
2 |
5 |
2 |
| 16-4500-A4 HYEN |
4,500 |
1,572 |
582 |
990 |
14,000 |
2 |
15,300 |
1 |
2 |
2-1/2 |
6 |
3 |
| 16-6000-A4 HYEN |
6,000 |
2,290 |
970 |
1,320 |
18,000 |
2 |
15,300 |
1 |
2-1/2 |
3 |
10 |
4 |
| Note (1) - total fuel required for generator. Based on nominal 1000 BTU/CF natural gas. |
| Note (2) - fuel to heat the system. Based on nominal 1000 BTU/CF natural gas. |
| Note (3) - fuel used to create the HYEN gas. Based on nominal 1000 BTU/CF natural gas. |
| For propane, fuel CFH requirements relate to equivalent BTU values. |
|
| |